Main Menu 
  Level Menu
  Quote Request

1
DL-500 Series Digital Levels


    800-251-1280


  • One Button Triggers Measurement and Data Storage
  • 0.6mm/0.8mm Height Accuracy
  • Advanced RAB Code Technology
  • Pre-installed Measurement Programs
  • Height Difference Measurement
  • Inverse Staff Reading for Ceiling Height
  • Internal Memory


Brochure

Specifications

Telescope DL-502 DL-503
Magnification 32X 28X
Objective aperture 45mm (1.78in.) 36mm (1.42in.)
Resolving power 3″ 3.5″
Field of view 1°20”
Minimum focus 1.5m (5.0ft.)
Image Erect
Stadia ratio 100

Compensator

Type Pendulum compensator with magnetic damping system
Working range ±15’

Accuracy (standard deviation for 1km double run leveling)

Electronic reading  
Invar staff 0.6mm 0.8mm
Fiberglass staff 1.0mm 1.5mm
Optical reading 1.0mm 2.0mm
Measuring range 1.6 to 100m (5.3 to 328ft.)
Measuring time  
Fine 3 sec. (single/continuous/average)
Tracking 1 sec.
Least count 0.0001/0.001m, 0.001/0.01ft., 1/8in.
Minimum brightness condition 20lx. at the staff surface

Distance measurement (D=measuring distance)

Accuracy  
D≦10m ±10mm (±0.4in.)
10m<D≦50m ±0.1%×D
50m<D ±0.2%×D
Least count 0.01/0.1m, 0.1/1ft., 1in

User interface

Display 128×32 dot matrix LCD with backlight
Keyboard 8 keys (7 on front panel, 1 on side panel)
Circular level sensitivity 10’/2mm

Measurement program

  Single / Continuous / Average / Elevation / Height difference / Cut & Fill / Stakeout distance

Data storage

Internal memory 2,000 points
JOB Max. 20 jobs
Data output format CSV

Interface

  RS-232C

Environmental

Water resistance IPX4 (IEC 60529:2001)
Operating temperature -20°C to 50°C (-4°F to 122°F)
Storage temperature -40°C to 70°C (-40°F to 158°F)

Others

  BDC46B (Li-ion battery, 7.2V)
Operating time Approx. 16 hours
Weight (including battery) 2.4kg (5.3 lb.)